LPV Series
0.8~12 Amp




LPV-100-24
Voltage
24V
Current
4.2 A

LPV-100-12
Voltage
12V
Current
8.5 A

LPV-60-24
Voltage
24V
Current
2.5 A

LPV-60-12
Voltage
12V
Current
5 A

LPV-35-24
Voltage
24V
Current
1.5 A

LPV-35-12
Voltage
12V
Current
3A

LPV-20-24
Voltage
24V
Current
0.84 A

LPV-20-12
Voltage
12V
Current
1.67 A
-
Constant Voltage Mode
-
LPV-60/100: 90~264VAC input LPV-150: 180~305VAC input only
-
LPVL-150: 90~132VAC input only
-
Withstand 300VAC surge input for 5 seconds (LPV-60/100)
-
Fully Encapsulated with IP67 level
-
Isolation class II, no F.G.
-
Class 2 power unit / Pass LPS (LPV-60-12/15/24/36/48 only)
-
Type HL LED Driver for use in Class I, Division 2 hazardous location luminaires (LPVL-150 only)
-
Economic, high reliability
-
Suitable for LED-based decorative/architectural lighting, LED stage, theater lighting, and LED electronic displays
-
Protections: Short circuit / Overload / Over voltage /Over temperature (LPV-150, LPVL-150 only)
-
1 years warranty
Feature
(for 12V, 12V Only)
(LPVL-150 only
(for 48V Only)
(for 12~36V)
85%
LPV-35 Series
Model No
Output
Tol.
R&N
Effi.
LPV-35-5
5V, 0~5A
±6%
80mV
77%
12V, 0~3A
±5%
120mV
84%
LPV-35-15
15V, 0~2.4A
±5%
120mV
84%
24V, 0~4.5A
±5%
150mV
LPV-35-36
36V, 0~1A
±5%
150mV
85%
LPV-20 Series
Model No
Output
Tol.
R&N
Effi.
LPV-20-5
5V, 0~3A
±5%
80mV
77%
12V, 0~6A
±1%
120mV
89.0%
LPV-20-15
15V, 0~5A
±1%
120mV
89.0%
24V, 0~3.2A
±1%
150mV
90.0%
Model No
LPV-20
LPV-35
LPV-60
LPV-100
AC input voltage range
General Specification
LPV-150
90~264VAC
90~264VAC; 127~370VDC
LPV-150: 180~305VAC; 254~431VDC LPVL-150: 90~132VAC
LPV-150: Cold start, 60A at 230VAC
LPVL-150: Cold start, 75A at 115VAC
AC inrush current (max.)
Cold start, 70A at 230VAC
Cold start, 55A at 230VAC
Cold start, 60A at 230VAC
Cold start, 75A at 230VAC
Overload Protection
110%~150% hiccup mode, auto-recovery
Over Voltage Protection
115%~135% rated output voltage
I/P-O/P: 3kVAC
Withstand voltage
Working temperature
-30~+70°C
-30~+65°C
-30~+70°C
-25~+70°C
-25~+65°C
Vibration
10~500Hz, 2G 10 minutes /1 cycle, period for 60 minutes each along X, Y, Z axes
Safety standards
LPV-20: TUV BS EN62368-1, UL879, UL1310, EAC TP TC 004 approved LPV-35: UL1310, IEC62368-1, EAC TP TC 004 approved
UL879 (except for LPV-60-5), UL1310 (except for LPV-60-5), IEC62368-1, EAC TP TC 004 approved
UL8750, UL879, EAC TP TC 004 approved;
IEC62368-1
EMC standards
BS EN55032 class B, BS EN61000-3-2 class A, BS EN61000-3-3, BS EN61000-4-2,3,4,5,6,8,11, EAC TP TC 020 FCC part 15 for LPVL-150 only, BS EN55024
Connection
Input
Output
UL rated, 18AWGx2C (60cm)
UL rated, 18AWGx2C (60cm)
UL rated, 16AWGx2C (60cm)
UL rated, 18AWGx2C (60cm)
UL rated, 16AWGx2C (60cm)
UL rated, 14AWGx2C (30cm)
UL rated, 18AWGx2C (30cm)
UL rated, 18AWGx2C (60cm)
UL rated, SJT18AWGx2C (60cm)
Dimension (LxWxH)
Packing
118x35x26 mm
0.22Kg; 60ps/14.2Kg/0.62CUFT
148x40x30 mm
0.34Kg; 40ps/14.6Kg/0.63CUFT
162.5x 42.5x 32 mm
0.4Kg; 32ps/13.8Kg/0.56CUFT
190x 52x 37 mm
0.63Kg; 20ps/13.6Kg/0.55CUFT
191x 63x 37.5 mm
0.74Kg; 20ps/15.8Kg/0.95CUFT


LPV-20 & LPV-35
INPUT
OUTPUT







LPV-75 & LPV-100
INPUT
INPUT
OUTPUT
LPV-150
INPUT

OUTPUT

88%
LPV-100 Series
(12V,24V only)
(for 12V, 12V Only)
Model No
Output
Tol.
R&N
Effi.
LPV-100-5
5V, 0~12A
±8%
80mV
80%
LPV-100-12
12V, 0~8.5A
±5%
120mV
85%
LPV-100-15
15V, 0~6.7A
±5%
120mV
87%
LPV-100-24
24V, 0~4.2A
±5%
150mV
LPV-100-36
36V, 0~2.8A
±5%
150mV
88%
86%