HLG series
150~240W
-
Constant voltage+constant current modes
-
Universal AC input (90 to 305VAC) / Full range
-
Meet 4kV surge immunity level (IEC61000-4-5)
-
Type HL LED Driver for use in Class I, Division 2 hazardous location luminaires
-
Suitable for outdoor LED lighting applications
-
Protections: Short circuit / Over current / Over voltage / Over temp.
-
1 years warranty
-
Multiple models for choice: Blank-Type: IP67 rated. Cable for I/O connection(For harsh environment) A-Type: IP65 rated. Io and Vo adjustable through built-in potentiometer B-Type: IP67 rated. 3 in 1 dimming function (1~10Vdc (for HLG-320H), 0~10V (for HLG-480H) , 10V PWM signal and resistance) AB-Type: IP65 rated. Io adjustable and Vo (for HLG-480H only) through built-in potentiometer & 3 in 1 dimming function. C-Type: Terminal block for I/O connection (HLG-320H only) D-Type(option): IP67 rated. Timer dimming function, contact MEAN WELL for details (HLG-320H only) D2-Type(option): IP67 rated. Smart timer dimming function* (HLG-480H only)
Feature
HLG-150H/185H
HLG-240H
ACL
ACN
FG
INPUT
Vo-
Vo+
OUTPUT
(Non-Dimming Models)
DIM-
DIM+
Vo-
Vo+
(Dimming Models)
OUTPUT
AC input voltage range
90~305VAC; 127~431VDC
AC inrush current (max.)
Cold start, 65A at 230VAC
DC adjustment range
±10% rated output voltage (A-Type only)
HLG-150H: 60%~100% ; HLG-185H/240H: 50%~100% via potentiometer (A-Type & HLG-240H C-Type)
Current adjustment range
95%~108% constant current limiting, auto-recovery
Over current protection
Over voltage protection
110%~140% rated output voltage
EMC standards
BS EN55015, BS EN55032 class B, BS EN61000-3-2 class C, BS EN61000-3-3, BS EN61000-4-2,3,4,5,6,8,11, BS EN61547, GB17743, GB17625.1, EAC TP TC 020,KC KN15,KN61547(except for AB,Dx,D2-type)
Over temp. protection
500ms, 50ms, 16ms
Setup, rise, hold up time
I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 1.5kVAC
Withstand voltage
-40~+90°C (refer to "OUTPUT LOAD vs TEMPERATURE")
Safety standards
UL8750, BS EN/AS/NZS61347-1,-2-13(except for HLG-240H C-Type), PSE J61347-1, J61347-2-13 , GB19510.14, GB19510.1, EAC TP TC 004 approved; UL1012, UL62368-1, TUV BS EN62368-1 approved for HLG-240H only; BIS IS15885(refer to spec for models), KC61347-1, KC61347-2-13(except for AB, C, D-type)
Connection
Please refer to page 66
Model No
Effi.
Tol.
Output
150mV
±2.5%
12V, 0~12.5A
HLG-150H-12 A
HLG-150H Series
= Blank,, A, B, AB, D or Blank
Cold start, 75A at 230VAC
±6% rated output voltage (A-Type & C-Type)
500ms, 80ms, 15ms at full load and 230VAC
A/B/D/Blank-Type: 244.2x 68x 38.8
C-Type: 251x 68x 38.8
228x 68x 38.8
Dimension (LxWxH)(mm)
Tol.
91.5%
92.0%
150mV
±2.0%
15V, 0~10.0A
HLG-150H-15 A
93.0%
150mV
±1.0%
20V, 0~7.50A
HLG-150H-20 A
93.0%
150mV
±1.0%
24V, 0~6.30A
HLG-150H-24 A
93.5%
200mV
±1.0%
30V, 0~5.00A
HLG-150H-30 A
93.5%
200mV
±1.0%
36V, 0~4.20A
HLG-150H-36 A
94.0%
200mV
±1.0%
42V, 0~3.60A
HLG-150H-42 A
94.0%
200mV
±1.0%
48V, 0~3.20A
HLG-150H-48 A
94.0%
200mV
±1.0%
54V, 0~2.80A
HLG-150H-54 A
Model No
Effi.
Tol.
Output
150mV
±2.5%
12V, 0~13.0A
HLG-185H-12 A
HLG-185H Series
Tol.
91.5%
92.0%
150mV
±2.0%
15V, 0~11.5A
HLG-185H-15 A
93.0%
150mV
±1.0%
20V, 0~9.30A
HLG-185H-20 A
93.5%
150mV
±1.0%
24V, 0~7.80A
HLG-185H-24 A
Model No
Effi.
Tol.
Output
200mV
±1.0%
24V, 0~6.20A
HLG-185H-30 A
Tol.
93.5%
93.5%
200mV
±1.0%
36V, 0~5.20A
HLG-185H-36 A
94.0%
200mV
±1.0%
42V, 0~4.40A
HLG-185H-42 A
94.0%
200mV
±1.0%
48V, 0~3.90A
HLG-185H-48 A
94.0%
200mV
±1.0%
54V, 0~3.45A
HLG-185H-54 A
= Blank,, A, B, AB, D or Blank
Model No
Effi.
Tol.
Output
150mV
±2.5%
12V, 0~16.0A
HLG-240H-12 A
HLG-240H Series
= Blank,, A, B, AB, D or Blank
Tol.
90.0%
90.0%
150mV
±2.0%
24V, 0~15.0A
HLG-240H-15 A
91.5%
150mV
±1.0%
36V, 0~12.0A
HLG-240H-20 A
92.5%
150mV
±1.0%
42V, 0~10.0A
HLG-240H-24 A
92.5%
200mV
±1.0%
42V, 0~8.00A
HLG-240H-30 A
92.5%
250mV
±1.0%
42V, 0~6.70A
HLG-240H-36 A
92.5%
250mV
±1.0%
42V, 0~5.72A
HLG-240H-42 A
93.0%
250mV
±1.0%
42V, 0~5.00A
HLG-240H-48 A
93.5%
350mV
±1.0%
42V, 0~4.45A
HLG-240H-54 A
R-41144061
(for 12,24,36,54A/B only)
IS 15885(Part 2/Sec13)
(except for B/AB/D-type)
(B Type)
Type HL
(except for B/AB/D-type)
(B Type)
Type HL
(except for B/AB/D-type)
(B Type)
Type HL
(except for B/AB/D-type)
(for 48V)
HLG series
320~480W
-
Constant voltage+constant current modes
-
Universal AC input (90 to 305VAC) / Full range
-
Meet 4kV surge immunity level (IEC61000-4-5)
-
Type HL LED Driver for use in Class I, Division 2 hazardous location luminaires
-
Suitable for outdoor LED lighting applications
-
Protections: Short circuit / Over current / Over voltage / Over temp.
-
1 years warranty
-
Multiple models for choice: Blank-Type: IP67 rated. Cable for I/O connection(For harsh environment) A-Type: IP65 rated. Io and Vo adjustable through built-in potentiometer B-Type: IP67 rated. 3 in 1 dimming function (1~10Vdc (for HLG-320H), 0~10V (for HLG-480H) , 10V PWM signal and resistance) AB-Type: IP65 rated. Io adjustable and Vo (for HLG-480H only) through built-in potentiometer & 3 in 1 dimming function. C-Type: Terminal block for I/O connection (HLG-320H only) D-Type(option): IP67 rated. Timer dimming function, contact MEAN WELL for details (HLG-320H only) D2-Type(option): IP67 rated. Smart timer dimming function* (HLG-480H only)
Feature
HLG-320H
HLG-480H
INPUT
OUTPUT
(Non-Dimming Models)
OUTPUT
AC input voltage range
90~305VAC; 127~431VDC
AC inrush current (max.)
Cold start, 70A at 230VAC
DC adjustment range
-15%~+13.3% rated output voltage (A-Type & C-Type)
HLG-150H: 60%~100% ; HLG-185H/240H: 50%~100% via potentiometer (A-Type & HLG-240H C-Type)
Current adjustment range
50%~100% via potentiometer (A-Type & HLG-320H C-Type only)
Over current protection
Over voltage protection
110%~140% rated output voltage
Over temp. protection
500ms, 80ms, 15ms at full load and 230VAC
Setup, rise, hold up time
I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 1.5kVAC
Withstand voltage
-40~+90°C (refer to "OUTPUT LOAD vs TEMPERATURE")
Safety standards
UL8750(type“HL”), CSA C22.2 No. 250.0-08; BS EN/AS/NZS 61347-1, BS EN/AS/NZS 61347-2-13, independent; GB19510.1, GB19510.14; IP65 or IP67 (except for HLG-320H C-type); J61347-1, J61347-2-13 (except for HLG-320H C-type), EAC TP TC 004; KC61347-1, KC61347-2-13(except for AB,C-type) approved
Connection
Please refer to page 66
Model No
Effi.
Tol.
Output
150mV
±3.0%
12V, 0~22.0A
HLG-320H-12 A
HLG-320H Series
= Blank,, A, B, AB, D or Blank
Cold start, 35A at 230VAC
-15%~+5% rated output voltage (A-Type only)
BS EN55015, BS EN55032 for HLG-320H only, BS EN61000-3-2 class C, BS EN61000-3-3, BS EN61000-4- 2,3,4,5,6,8,11,BS EN61547, GB17743, GB17625.1, EAC TP TC 020,KC KN15,KN61547(except for AB,Dx,D2-type
EMC standards
Tol.
91.0%
92.5%
150mV
±2.0%
15V, 0~19.0A
HLG-320H-15 A
93.5%
150mV
±1.5%
20V, 0~15.0A
HLG-320H-20 A
94.0%
150mV
±1.0%
24V, 0~13.34A
HLG-320H-24 A
94.0%
200mV
±1.0%
30V, 0~10.7A
HLG-320H-30 A
94.5%
250mV
±1.0%
36V, 0~8.90A
HLG-320H-36 A
95.0%
250mV
±1.0%
42V, 0~7.65A
HLG-320H-42 A
95.0%
250mV
±1.0%
48V, 0~6.70A
HLG-320H-48 A
95.0%
350mV
±1.0%
54V, 0~5.955A
HLG-320H-54 A
Model No
Effi.
Tol.
Output
200mV
±1.0%
24V, 0~20A
HLG-480H-24 A
Tol.
94.0%
94.5%
200mV
±1.0%
30V, 0~16A
HLG-480H-30 A
95.0%
250mV
±1.0%
36V, 0~13.3A
HLG-480H-36 A
95.0%
250mV
±1.0%
42V, 0~11.4A
HLG-480H-42 A
94.5%
250mV
±1.0%
48V, 0~10A
HLG-480H-48 A
= Blank,, A, B, AB, D or Blank
UL8750(type“HL”), CSA C22.2 No. 250.0-08; BS EN/AS/NZS 61347-1, BS EN/AS/NZS 61347-2-13, independent; GB19510.1, GB19510.14; IP65 or IP67 (except for HLG-320H C-type); J61347-1, J61347-2-13 (except for HLG-320H C-type), EAC TP TC 004; KC61347-1, KC61347-2-13(except for AB,C-type) approved
Dimension (LxWxH)(mm)
252x 90x 43.8
262x 125x 43.8
HLG-480H Series
95.0%
350mV
±1.0%
54V, 0~8.9A
HLG-480H-54 A
(except for B/AB/D-type)
(AB/B-Type)
Type HL
(except for AB, C-type)
(except for B/AB/D-type)
(AB/B-Type)
(except for AB, D, D2-type)
Type HL
DIM-
DIM+
Vo-
Vo+
Vo-
Vo+
ACL
ACN
FG
HLG series
600W
-
Constant voltage+constant current modes
-
Universal AC input (90 to 305VAC) / Full range
-
High efficiency up to 96%
-
Meet 4kV surge immunity level (IEC61000-4-5)
-
No load power consumption <0.5W at remote off (HLG-600H)
-
Type HL LED Driver for use in Class I, Division 2 hazardous
-
location luminaires
-
LED indicator for power on (A-Type only)
-
Suitable for outdoor LED lighting applications
-
Protections: Short circuit / Over current / Over voltage / Over temp.
Feature
HLG-600H
ACL
ACN
FG
INPUT
Vo-
Vo+
Vo+
Vo-
Vo+
RC-&
RC+
OUTPUT
(Non-Dimming Models)
Vo+
Vo-
Vo-
Vo+
+5V
RC-&GND
RC+
DIM-
DIM+
SB
(Dimming Models)
OUTPUT
AC inrush current (max.)
Cold start, 70A at 230VAC
DC adjustment range
-15%~+13.3% rated output voltage (A-Type & C-Type)
Current adjustment range
50%~100% via potentiometer (A-Type & HLG-320H C-Type only)
Safety standards
UL60950-1, UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC BS EN61347-1, BS EN61347-2-13 independent, BS EN62384,IP65 or IP67, J61347-1, J61347-2-13, CCC GB4943.1, EAC TP TC 004, AS/NZS 60950.1(by CB),KC61347-1, KC61347-2-13(for 24A,36A,48A,54A only) approved
Model No
Effi.
Tol.
Output
150mV
±3.0%
12V, 20~40A
HLG-600H-12 A
HLG-600H Series
Tol.
92.0%
93.5%
150mV
±2.0%
15V, 18~36A
HLG-600H-15 A
94.5%
150mV
±1.5%
20V, 14~28A
HLG-600H-20 A
95.0%
150mV
±1.0%
24V, 12.5~25A
HLG-600H-24 A
95.0%
200mV
±1.0%
30V, 10~20A
HLG-600H-30 A
Model No
Effi.
Tol.
Output
250mV
±1.0%
36V, 8.7~16.7A
HLG-600H-36 A
Tol.
95.5%
96.0%
250mV
±1.0%
42V, 7.1~14.3A
HLG-600H-42 A
96.0%
250mV
±1.0%
48V, 6.2~12.5A
HLG-600H-48 A
96.0%
350mV
±1.0%
54V, 5.6~11.2A
HLG-600H-54 A
= Blank,, A, B, AB
AC input voltage range
90~305VAC; 127~431VDC
-15%~+5% rated output voltage (A-Type only)
95%~108% constant current limiting, auto- recovery
Over current protection
110%~140% rated output voltage
Over voltage protection
500ms, 80ms, 15ms at full load and 230VAC
Over temp. protection
II/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 1.5kVA
Setup, rise, hold up time
-40~+90°C (refer to "OUTPUT LOAD vs TEMPERATURE")
Withstand voltage
UL60950-1, UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC BS EN61347-1, BS EN61347-2-13 independent, BS EN62384,IP65 or IP67, J61347-1, J61347-2-13, CCC GB4943.1, EAC TP TC 004, AS/NZS 60950.1(by CB),KC61347-1, KC61347-2-13(for 24A,36A,48A,54A only) approved
Safety standards
Please refer to page 66
Connection
280x 144x 48.5
Dimension (LxWxH)(mm)
(24A,36A,48A,54A)
Type HL
(AB/B-Type)